Sök:

Sökresultat:

545 Uppsatser om Absorption cooling machine - Sida 1 av 37

Kyla i Nyköping och Motala : Kartläggning av kylapotential för Vattenfall Värm

The Swedish energy company Vattenfall is currently the owner of the district heatingsystems in Nyköping and Motala. To be able to also offer cooling solutions tocustomers are becoming more and more important. This report describes the resultsof an investigation of the cooling market in the two cities and the potential needs forcooling today and in the coming 20 years. The total potential for the coming 20 yearsis estimated to be roughly 17 MW for Nyköping and 9 MW for Motala.Two possible district cooling systems for each of the two city centers was modeledand a comparison was made between different cooling techniques namely absorptionand compressor chillers.Absorption chillers driven with district heating during the summer is one way ofincreasing the load in a combined heat and power plant and thereby the possibleelectricity generation. The cost of heat production must be low for absorption chillerto be able to compete as an alternative.

Kylapotentialen i Drefviken för Vattenfall Heat AB

Vattenfall Heat AB is a district heat provider in Drefviken, but has yet to establish any cooling systems in this area. This thesis examines the potential client base within the area today and over the coming 20 years. The feasibility of the most common cooling technologies is evaluated and results show a total potential for an installed capacity of 30 MW providing 50 GWh of cooling per year. One of the examined areas shows good prospect for heat driven absorption chillers during the summer months when the heat load is limited..

Analys av sorptiv kylning i industri- och kontorsbyggnader

Energy efficiency is important both to reduce costs and to reduce greenhouse gas emissions in the atmosphere. Reducing costs will also help maintain business competitiveness.Scania in Södertälje is a company where the optimization of energy use is an ongoing and continual process. One area with potential to make energy and cost savings is the effectiveness of the ventilation systems in offices and industrial premises at Scania. During the summer months an increased demand for cooling occurs, leading to increased ventilation and a peak in district cooling system usage. Sorptive cooling is a technology where the supplied air is cooled by applying external heat.

Kyla på Swedavia Stockholm Arlanda : Kartläggning av nuvarande fjärrkylasystem och framtida utvecklingsmöjligheter

Arlanda airport is Sweden?s largest airport. The demand for comfort cooling of the airport?s buildings is high and is mainly provided by district cooling. District cooling is based on the same principle as district heating.

Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp

The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.

Bergkyla och bergvärmeutredning för industrilokalen Rödbergsmyran 5 i Umeå, Västerbotten.

Grubbe Ventilation AB is a sheet metal and ventilation company who provides design, installation, service, and repair of ventilation. The company is expanding their business by building a new facility in Umeå, Västerbotten. The property is designed to be used for both office and industrial work.Grubbe Ventelation AB has not yet decided upon wish system which is to be established to provide the building with heating and cooling. The consulting firm Umeå Projekt Team has therefore been asked to investigate the possibilities to invest in geothermal- heating and cooling.If the investigation of a geothermal heating- and cooling system would provide favorable results it would be a very appropriate alternative that provides energy at low costs and are an environmentally friendly option as the energy comes from stored solar energy in the ground is provided by stored solar energy in the ground.The facility ´s heating and cooling consumptions are calculated in the program BV2 and the result indicate a heating demand of 185 000 kWh per year due to thermal transmittance, transmission losses, heating of warm water and a cooling requirement of 5500 kWh.Three different systems of geothermal heating and cooling were tested in the computer program Energy Earth Design. The results show no difference in the dimensioning of the drill hole if merely heating were to be used or both heating and cooling were to be established.

Restvärmeåteranvändning från absorptionsvärmepumpar : en kartläggning av möjligheter och begränsningar vid Vattenfall Värme Uppsala Block 5

Vattenfall district Heating power plant in Uppsala produces district cooling with absorption heat pumps which leads to a large amount of waste heat that has to be cooled with evaporative cooling towers. The Environmental Court has ordered Vattenfall to survey the possibilities to recover the heat, which is the focus of this thesis.The study begins with an overview of the system, and conditions and limitations for waste heat recovery is examined. In the next step alternatives to recycle the heat is evaluated, either by direct recovering or by upgrading.First, the technical possibility of each alternative is discussed, and then the operation time and the amount of recovered heat is calculated. Those alternatives which are possible are brought further to an economic analysis.The cost of investment for each alternative constitutes the basis for a present value analysis. The results are put together in a table where the total amount of recovered heat is compared with the present value for the different alternatives.

Effektivisering av kylsystem på Utö värdshus

Energy consumption is at present a major political issue, and numerous projects that comprise many nations are currently in process to increase energy efficiency and bring down energy dependency. As a member state of the EU, Sweden now faces the challenge of implementing substantial energy-saving measures until the year 2016. One of these measures is the project ?Green Islands? financed by the EU that intend on creating sustainable islands in areas around the Baltic Sea. The Archipelago Foundation leads the project that concerns the Stockholm archipelago, where focus has been placed upon decreasing energy usage in businesses and services on Utö among other islands.

En analys av centralkylan i Slakthusområdet i Stockholm

In Stockholm, Johanneshov the Slaughterhouse area (Slakthusområdet) can be found. A number of companies have gathered there providing the Stockholmers with meat products. This area has a great need for cooling to supply large cold storages. To facilitate this, a central cooling system has been built, supplying the area with effective and safe cooling.The aim of this master thesis study is to give hints to energy efficient and reliable changes that can be put in place at a low marginal cost depending on the future activities in the area. The suggested changes will be presented to the company Bravida (managing the system), which also desires a deeper understanding of the energy flows through the central cooling system.Firstly visiting the site with proper guidance, we have then tried to understand the function of the system including which machines and media that are used.

Uppskärningsmaskin : Underlag till CE-märkning

Abstract (in English)The work that lead to a CE- marking and the creation of a total drawing foundation on an existing machine carried out on the company Polytec Composites Sweden AB in Ljungby. The company have design an machine that exist in six example that runs in the production. To be able to use the machine the company have to work out a CE-marking. The process that summed up all the document that needs for the machine to make a CE-marking. The documentation includes a total drawing over the machine and a risk analysis performed by a group employers on the company.

Beredning av köldbärare för komfortändamål i kontorsverksamhet : En studie i produktionsslag

The real estate company Ihus is facing an expansion of its comfort cooling in Noatun,Uppsala, to provide the buildings in the block with cooling. The buildings in Noatunare mainly used for office premises, where the requirements for an accepted indoorclimate is great. However, it?s uncertain whether Ihus should continue, as currently,producing comfort cooling by themselves using a compressor chiller, or if they shouldconnect themselves to Vattenfall?s district cooling net.The purpose of this report is to examine which technique of cooling is best suited forIhus and their buildings in Noatun. It should also work as a guideline for othercompanies facing the same problem as Ihus.

Life Cycle Cost : Studie om LCC som verktyg att utva?rdera geoenergianla?ggningar

Life Cycle Cost, often abbreviated as LCC, is a common tool for comparing the total cost of different alternatives, such as heating and cooling methods. Common heating and cooling methods in Sweden are geothermal energy, district heating and district cooling. This report aims to evaluate how different heating and cooling methods differ from each other while being applied on three different types of buildings, using selected LCC-models. Information about the selected LCC-models wasretrieved from each separate model and its website. Reports and agencies were used as sources for information about the heating and cooling methods.

Varför lämnar maskinförare skogsbranschen? :

Resignations are common in all business sectors and can also be found among forest machine operators in the forest business. As the industry today faces a lack of forest machine operators it is justified to determine why machine operators choose to quit their jobs. The aim of this study was to a) find out the number of machine operators that have resigned b) identify and analyse the cause for these resignations c) identify the reasons why the machine operators started to work in the forest and d) give suggestions on different measures that will limit resignations amongst forest machine operators. A questionnaire was sent to machine operators who have quit working as employees, contractors or as employees for contractors with Holmen Skog during 2003-2007. 32 machine operators responded to the questionnaire. Interviews were made with 10 machine operators who had answered the questionnaire to gather more qualitative data. The results of the study indicate that fewer forest machine operators change profession than employees in other occupations in Sweden.

Kryogen uppgradering av biogas med kyla från värmedriven absorptionskylmaskin

Detta är ett examensarbete som genomförts hos Göteborg Energi AB och syftar till att utreda omkryogen uppgradering av biogas med fördel kan ske genom att producera nödvändig kyla medvärmedriven absorptionskylmaskin. Göteborg Energi är en av tre parter som tillsammans ska bygga enbiogasanläggning i Lidköping som ska vara i drift 2010. Anläggningen ska producera 30 GWhflytande biogas per år.Arbetet utreder om det är fördelaktigt ur ekonomiskt, energimässigt och miljömässigt perspektiv attuppgradera biogas med kryogen teknik med värmeproducerad kyla. En jämförelse görs först medkryogen teknik där kylan är producerad med el och sen med andra uppgraderingstekniker. Som stödhar två olika processimuleringsprogram används, Hysys och DESIGN II.Resultatet visar att energianvändningen ökar då värmedriven kyla används i jämförelse med kylaproducerad med el.

Energianvändning i serverhallar: energiflöden och kylning

This thesis examines different methods for the cooling of data centers. Several means of cooling with the refrigeration cycle have been studied, as well as the feasibility of using free cooling in different parts of Sweden. In addition, the possibilities of transferring excess heat to a nearby district heating system were investigated. It was found that in all investigated cases except two, the data center could be cooled solely with free cooling for at least 300 days a year when only the outside air temperature was considered as a constraining factor. The limit was then set to 20 °C.The vast majority of all district heating systems in Sweden get little to none of their heat from other excess heat sources.

1 Nästa sida ->